Sentinel Kinetic Plus B 443028

Sentinel Kinetic Plus B 443028

VEN 443028

£1,300.21 ex. vat £1,560.25 inc. vat

Usually ships in 5 working days

Vent Axia Sentinel Kinetic Plus B 443028 VENT AXIA SENTINEL PLUS B

Details

Vent Axia 443028 Lo Carbon Sentinel Kinetic Plus
Shared Accommodation and Multiple Occupancy Heat Recovery Unit


The Sentinel Kinetic Range incorporates:
A wholehouse heat recovery system with up to 92% energy efficiency. An easily accessible heat recovery cube protected by two removable EU3 filters. Two Lo-Carbon Energy Saving EC DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built in condensation drain. Specifically designed for new build constructions with a high level of insulation.

Lo-Carbon Sentinel Kinetic meets the latest requirements of the Building Regulations Document F 2006 for wholehouse system ventilation: System 4. Continuous mechanical supply and extract with heat recovery. The Lo-Carbon Sentinel Kinetic models have 3 fully adjustable speeds and a purge setting - maximum. On the front of the unit is a digital controller that can be used to pre-set the speeds to any required air-flow within the performance range.

Integral Humidity Sensor
The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. Night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from only 20dB(A) @3m

Features and Benefits

Manufactured in the UK
Building Regulations Part F compliant
SAP Appendix Q Eligible
Energy Savings Trust best practice compliant
Up to 92% heat recovery whilst controlling condensation
Programmable Summer bypass
Left or right hand installation
Horizontal and/or vertical duct outlets
Integrated digital controller for simple and accurate commissioning
Light-weight for easy installation
External condensate connection
Plug and play controls; Humidistat, Vent-Wise, Wireless remote
BMS connectivity
LS inputs/(Light Switch)
Volt-free inputs
Self diagnosis for simplified fault finding
Adjustable delay on/delay off timer


Multiple control options:

Five Volt-free pairs of switch terminals for sensor inputs allow boosting from a full range of Vent-Axia controllers - humidistats, PIR, timers. Two terminals with 0-24V outputs allow 0V to 10V proportional control by sophisticated controllers such as CO2 sensors and proportional humidistats. The optional Vent-Wise controller senses temperature rise in a bath/shower hot water supply and/or current in a cooker/hob electrical circuit to activate boost, ensuring additional ventilation when needed. Switched-live for boosting via light switches (220-240 V AC) or manual Normal/Boost switches. This connection has the advantage of Delay-On and Delay-Off facility. Delay-On enables you to prevent the Boost airflow between 0 and 10 minutes, after a light switch has been activated. Delay-Off allows the Boost airflow to continue after a light switch is turned off to ensure effective clearance of humidity. This timer is adjustable between 0 and 25 minutes.

Purge setting:
The unit can be set to maximum flow (100%) by pressing and holding the Boost button on the unit itself or optional wireless controller for 5 seconds. Purge will continue for two hours unless cancelled by pressing the Boost button again.

Summer Bypass
An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre set 'Comfort temperature' the bypass damper closes.
Anti-frost protection: In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperatures below zero.

Cooker Hood System range
System canopy hoods are a motorless hood with extract being provided by the MVHR unit. When the boost button on the canopy is activated, the MVHR unit goes to boost setting and the summer bypass opens preventing cooking by-products entering the heat exchanger cell.
Wired Remote Controller (option)
Supplied with 15 metres of cable (max length), the Wired Remote Controller duplicates all the features of the on-board control panel, allowing commissioning, diagnosis and user control. Flush mounting, suitable for a single gang patrass box 16mm deep.

Easy Installation
The Sentinel Kinetic models can be mounted vertically in a roof space, and are suitable for wall mounting or within a kitchen cupboard. When mounted in an unheated area ducting should be insulated. Ducting can be attached to the unit horizonally, vertically or both. Minimum internal depth of kitchen cupboard: V&B models 290mm. CW models 300mm V&B Models

Left or right hand installation.
The unit is supplied with duct spigots to outside on the right hand side. These can be reversed onsite by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel.

Horizontal and vertical spigots:
The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. Condensate drain can be taken out through the back, or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation.

Cooker Hood Unit
The Sentinel Kinetic Cooker Hood is designed to fit in a 600mm aperture above a hob. The telescopic hood incorporates two flat removable metal grease filters, low energy light bulbs and is available with White or Brushed Aluminium front trim. The hood contains an integral fire damper in accordance with BRE Digest 398 and is connected to the heat recovery unit by a galvanised steel duct with access for cleaning. When the hood is opened, the heat recovery unit goes to boost speed and the summer bypass automatically opens to prevent cooking by-products entering the heat recovery cell. As an additional safety feature, the duct also contains a thermal cut-out fuse which turns off the MVHR unit in the event of excessive temperature in the airway. Cooker Hood units cannot be handed on-site and must be purchased as left hand or right hand models.